Answer one question at a time. You start with the checks that are safe to do yourself, and stop at the point where a technician is needed, knowing what the repair should cost.

Short answer

When a home AC runs but is not cooling, the cause is most often a clogged air filter, a failed capacitor on the outdoor unit, or low refrigerant from a leak. Check the filter and the thermostat first: they cost nothing to fix.

DIAGNOSIS
1 · Which system?
2 · What is happening?

Choose what is happening to start.

AC not blowing cold air (running but not cooling)

Work through these 6 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check the thermostat settings. Mode on COOL, fan on AUTO (not ON), and the set temperature at least 3°F below the room. With the fan on ON, the blower keeps pushing air even when the AC is not cooling.
  2. Pull the air filter and look at it. If you cannot see light through it, replace it. A clogged filter starves the coil of air, which cuts cooling and can freeze the coil.
  3. Look at the outdoor unit while it runs. The top fan should spin and you should hear the compressor hum. Clear leaves, grass and anything within 2 feet. If the fan is still but the unit hums, turn the system off: that is usually a failed capacitor.
  4. Check both breakers. Central AC has one breaker for the indoor unit and one for the outdoor unit. Reset a tripped one once. If it trips again, leave it off and call a technician.
  5. Look for ice on the copper lines. Ice on the large copper line or the indoor coil means the system froze. Switch cooling OFF and the fan to ON for 2–4 hours to thaw it before running it again.
  6. Measure the temperature split. After 15 minutes of running, the air from a supply vent should be about 15–20°F cooler than the air going into the return. Much less than that points to refrigerant or coil problems.
Likely causeRepair cost
Dirty air filter
The most common cause, and a $10 fix.
DIY
Failed capacitor
Outdoor unit hums but the fan does not spin.
$100–$250
Dirty condenser coil
The outdoor unit cannot shed heat on hot days.
$100–$400
Low refrigerant (leak)
Small temperature split, ice on lines, hissing.
$200–$1,500
Bad contactor
Outdoor unit will not start at all.
$200–$450
Failing compressor
Fan runs, compressor does not; breaker trips.
$600–$2,500

AC not turning on

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check the thermostat screen. A blank screen usually means dead batteries or a tripped breaker on the air handler. Replace the batteries first.
  2. Check the breakers and the outdoor disconnect. Reset a tripped breaker once. Also check the pull-out disconnect box next to the outdoor unit and the service switch near the indoor unit (it looks like a light switch).
  3. Look at the condensate drain pan. Many systems have a float switch that shuts the AC off when the drain backs up. Water in the pan means the drain line is clogged: clearing it often brings the AC back.
  4. Make sure the furnace or air handler door is closed. A safety switch behind the access panel cuts power when the panel is loose.
Likely causeRepair cost
Thermostat batteries or settings
Blank or unresponsive thermostat.
DIY
Tripped breaker or blown fuse
One reset is fine; repeated trips mean an electrical fault.
$75–$300
Clogged condensate drain (float switch)
Water in the pan, AC dead.
$75–$250
Failed thermostat
Fresh batteries, still no response.
$140–$350
Control board
Power is present but nothing starts.
$150–$700

AC leaking water inside the house

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Turn the AC off and protect the area. Turning it off stops more condensate from forming. Put towels or a pan down if water reaches a ceiling or floor.
  2. Clear the condensate drain line. Find the PVC pipe where it exits outside and pull the clog out with a wet/dry vacuum for 1–2 minutes. Then pour a cup of white vinegar into the access tee near the indoor unit.
  3. Check the filter. A clogged filter can freeze the coil, and the melting ice overflows the pan.
  4. Check the condensate pump, if you have one. A small box with a tube near the unit. Pour water in; it should start pumping. If it does not, it has failed.
Likely causeRepair cost
Clogged condensate drain line
Algae and sludge build up every season. Most common cause.
$75–$250
Frozen coil melting
Dirty filter or low refrigerant.
DIY
Failed condensate pump
Pump does not run when filled.
$100–$450
Rusted or cracked drain pan
Common on units older than 10–15 years.
$200–$600

AC frozen: ice on the lines or coil

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Turn cooling OFF, fan ON. Let it thaw for 2–4 hours. Never chip the ice off: you can puncture the coil.
  2. Replace the air filter. Restricted airflow is the number-one cause of a frozen coil.
  3. Open vents and clear the returns. Closing too many supply vents or blocking the return grille with furniture lowers airflow.
  4. Run it again and watch for 30 minutes. If ice comes back with a clean filter and open vents, the cause is refrigerant or the blower. That needs a technician.
Likely causeRepair cost
Dirty filter / blocked airflow
Fix and the ice does not return.
DIY
Low refrigerant (leak)
Ice returns even with good airflow.
$200–$1,500
Weak blower motor
Low airflow at every vent.
$300–$900
Dirty evaporator coil
Years without cleaning.
$100–$400

AC outside unit not running

Work through these 3 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Confirm the thermostat is calling for cooling. COOL mode, set below room temperature. Wait 5 minutes: many thermostats delay the outdoor unit to protect the compressor.
  2. Check the outdoor breaker and disconnect. Reset once if tripped. Repeated trips mean an electrical or compressor fault.
  3. Listen at the unit. A hum with no fan movement usually means a dead capacitor. Turn power off. Capacitors hold a dangerous charge even when off: do not touch it.
Likely causeRepair cost
Failed capacitor
Hum, no spin. The most common summer failure.
$100–$250
Bad contactor
Silent unit with power at the disconnect.
$200–$450
Condenser fan motor
Compressor runs, fan does not.
$200–$700
Tripped breaker / fuse
Disconnect fuses can blow.
$75–$300
Compressor failure
Trips the breaker on every start.
$600–$2,500

Thermostat blinking "Cool On"

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Wait five minutes. A flashing "Cool On" usually means the thermostat is running its compressor-protection delay. After a power blip or a settings change it waits up to about 5 minutes before starting the AC. If it starts cooling after that, nothing is wrong.
  2. Replace the thermostat batteries. Weak batteries can keep the thermostat from sending a steady call for cooling, even when the screen still lights up.
  3. Check the AC breaker and outdoor disconnect. If the outdoor unit has no power, the thermostat keeps calling for cooling that never arrives. Reset a tripped breaker once.
  4. Check the drain pan and the furnace door. A float switch tripped by a clogged drain, or a loose access panel, opens a safety circuit and blocks cooling while the thermostat keeps waiting.
Likely causeRepair cost
Normal compressor delay
Stops flashing within about 5 minutes.
DIY
Weak thermostat batteries
Flashing returns, screen dims.
DIY
Tripped breaker or fuse
Outdoor unit silent.
$75–$300
Clogged drain (float switch)
Water in the drain pan.
$75–$250
Thermostat or wiring fault
Keeps flashing for hours.
$140–$350
Control board
Power is fine but the call never reaches the unit.
$150–$700

Furnace not turning on (no heat)

Work through these 5 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check the thermostat. HEAT mode, set a few degrees above the room temperature, fresh batteries.
  2. Check the furnace power switch and breaker. There is usually a light-style switch on or near the furnace. Make sure it is ON and the breaker has not tripped.
  3. Replace the filter. A clogged filter overheats the furnace and trips the high-limit safety, which shuts the burners down.
  4. Check the gas supply. The valve handle on the gas pipe should be parallel to the pipe. If your gas stove works, gas service is on.
  5. Read the status light. Most modern furnaces blink an error code through a small window in the lower panel. Match the blink pattern to the chart on the inside of the furnace door, and give that code to the technician.
Likely causeRepair cost
Thermostat or settings
Batteries, wrong mode, or a dead thermostat.
$140–$350
Failed ignitor
Inducer runs, burners never light.
$100–$250
Dirty flame sensor
Burners light, then shut off within seconds.
$80–$250
High-limit switch tripping
Overheating, usually from a clogged filter.
$100–$375
Draft inducer motor
No startup hum, or a loud grinding motor.
$400–$1,100
Control board
No status light, or erratic behavior.
$300–$650

Furnace blowing cold air

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check the fan setting. If the thermostat fan is on ON, the blower runs between heating cycles and moves unheated air. Set it to AUTO.
  2. Give it two minutes. It is normal for the first 30–90 seconds of air to be cool while the heat exchanger warms up.
  3. Watch the burners through the window. If they light and go out after a few seconds, the flame sensor is the usual suspect.
  4. Replace the filter. An overheating furnace shuts off its burners but keeps the blower running, blowing cool air.
Likely causeRepair cost
Fan set to ON
Fixed at the thermostat.
DIY
Dirty flame sensor
Short burner flame-outs.
$80–$250
Overheating / limit switch
Clogged filter or blocked vents.
$100–$375
Ignitor
Burners never light.
$100–$250
Gas valve
Ignitor glows but no gas flows.
$200–$800

Furnace short cycling (turns on and off)

Work through these 3 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Replace the filter. Overheating trips the limit switch, the furnace cools, restarts, and repeats.
  2. Check the thermostat location. A thermostat near a supply vent, a lamp or a sunny window reaches its set point too fast.
  3. Open supply vents and clear returns. Restricted airflow causes overheating.
Likely causeRepair cost
Clogged filter / overheating
The most common cause.
DIY
Dirty flame sensor
Ignites, runs seconds, stops.
$80–$250
Thermostat
Bad location or failing sensor.
$140–$350
Oversized furnace
Heats the house in minutes, then stops. Address at replacement.
—

Heat pump not heating

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check the thermostat mode. HEAT, not COOL. "EM HEAT" or "AUX" means backup electric strips are running, which works but costs much more.
  2. Replace the filter. Heat pumps deliver gentler, lower-temperature heat, so airflow matters even more than with a furnace.
  3. Clear the outdoor unit. Remove snow, leaves and ice around and on top of it. Keep 2 feet clear.
  4. Check both breakers. One feeds the outdoor unit, one the indoor air handler and its backup heat strips.
Likely causeRepair cost
Thermostat mode or settings
Wrong mode or failing thermostat.
$140–$350
Failed capacitor
Outdoor unit hums but does not run.
$100–$250
Low refrigerant (leak)
Runs constantly, weak heat.
$200–$1,500
Defrost / control board
Outdoor coil stays iced over.
$150–$700
Compressor
Outdoor unit fan runs, no heat.
$600–$2,500

Heat pump frozen: ice on the outdoor unit

Work through these 4 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Know what is normal. A light white frost in cold, damp weather is normal. The unit melts it every 30–90 minutes in a defrost cycle (you may see steam).
  2. Check for water dripping onto it. A leaking gutter dripping on the unit builds thick ice that defrost cannot clear.
  3. Pour warm (not hot) water to clear it. With the system off, rinse the ice away. Never chip or scrape the fins.
  4. Watch the next cycle. If a solid block of ice comes back within hours, the defrost system has failed.
Likely causeRepair cost
Defrost control / board
Never enters defrost.
$150–$700
Low refrigerant
Coil runs too cold and ices up fast.
$200–$1,500
Outdoor fan motor
Fan stopped, coil ices.
$200–$700
Water dripping on unit
Fix the gutter.
DIY

Heat pump blowing cold air

Work through these 3 checks in order; they are safe for homeowners. If none fixes it, the likely causes and repair costs are below. Run it step by step →

  1. Check whether it is defrosting. During defrost the system briefly runs in cooling mode for a few minutes. Cool air for 2–10 minutes in winter is normal.
  2. Hold your hand at a vent for a minute. Heat pump air feels lukewarm (about 90–100°F) compared with a furnace. That is normal too.
  3. Confirm HEAT mode. If the thermostat was swapped recently, the O/B wire may be configured backwards, so the system cools when it should heat.
Likely causeRepair cost
Normal defrost or lukewarm air
No repair needed.
DIY
Thermostat configuration
Cools in heat mode after a thermostat change.
$140–$350
Low refrigerant
Air stays cool for long periods.
$200–$1,500
Control board
Stuck in defrost or wrong mode.
$150–$700

When to stop and call a technician

  • A breaker trips a second time after one reset.
  • You see ice return after a full thaw with a clean filter.
  • You smell burning, gas, or hear banging at furnace startup.
  • The fix involves refrigerant, gas valves, or the capacitor (it holds a dangerous charge).

A diagnostic visit costs $75–$200. Tell the technician which checks you already did; it saves time on the clock. See repair prices by part →

Next toolRepair Cost

Questions homeowners ask

Why would my AC be running but not cooling?

The usual causes, in order of likelihood: a clogged air filter, the thermostat fan set to ON, a dirty outdoor coil, a failed capacitor (outdoor fan not spinning), or low refrigerant from a leak.

Should I turn off my AC if it is not cooling?

Yes. Running a system that is not cooling can freeze the coil or overheat the compressor, turning a small repair into a big one. Switch cooling off and leave the fan on if you see ice.

How do I reset my central AC?

Turn the thermostat off, switch off the AC breaker for 30 seconds to a minute, switch it back on, then set the thermostat to COOL and wait 5 minutes. Some outdoor units also have a red reset button near the bottom of the cabinet. Reset only once; if it fails again, there is a fault to fix.

Why did my AC suddenly stop blowing cold air?

A sudden stop on a hot day is very often a failed capacitor or contactor at the outdoor unit: inexpensive parts ($100–$450) that fail under heat. A tripped breaker or a full condensate float switch can do the same.

Why is my thermostat blinking "Cool On"?

Most thermostats flash "Cool On" while they wait out a compressor-protection delay of up to about 5 minutes after a power interruption or a setting change. That is normal. If it keeps flashing much longer, check the batteries, the AC breaker and the condensate drain float switch.

Why is my AC not turning on?

Start with the thermostat (mode, set point, batteries), then the two breakers and the outdoor disconnect, then the condensate drain: a clogged drain trips a float switch that shuts the AC off. If all of those check out, a failed contactor, capacitor or control board is the usual cause.

Why is my AC leaking water inside?

Almost always a clogged condensate drain line. Other causes are a frozen coil melting (dirty filter or low refrigerant), a failed condensate pump or a rusted drain pan. Turn the system off and clear the drain line first.

Why is my furnace blowing cold air?

Check that the thermostat fan is set to AUTO, not ON. If it is, the furnace may be overheating from a clogged filter, or a dirty flame sensor is shutting the burners off seconds after they light.

Is ice on my heat pump normal?

A light frost in winter is normal and melts in the next defrost cycle. A thick block of ice that does not clear within a few hours is not; it points to a defrost control, fan, or refrigerant problem.