Furnace blinking red light? Decode the error code by brand
Pick the brand on your furnace’s label, tell us what kind of light or display the control board has, and tap what you see. You get what the manufacturer says it means, what you can safely check yourself, and what the fix usually costs.
A blinking light on the furnace control board is a fault code: count the flashes between pauses and match them with the chart inside the furnace door. On most boards a steady light means power and no fault. The most common faults are an open limit (often a dirty filter), a pressure switch or vent problem, and an ignition lockout.
Choose a brand, a board type and what you see.
How to read your furnace’s blinking light
Read the code before you turn anything off. Removing power or the blower door can erase the code on some boards, and the door switch cuts power to the control.
- Remove only the outer (burner) door if needed and look through the small window in the blower door, or at the board itself.
- Watch at least two full cycles. Count the flashes between the long pauses. On Carrier boards, count the short flashes, then the long ones.
- Note the color (red, green, amber) and whether it is steady, slow or rapid.
- Compare with the chart printed on the inside of the furnace door or the wiring diagram. If it differs from this page, trust the label: it belongs to your board.
- Reset the power once at most. Carrier and Lennox lockouts clear themselves after 1–3 hours; resetting again and again only hides the fault.
What 1 to 9 flashes mean on each brand
The same number of flashes means different things on different brands. Three flashes is a pressure switch problem on Goodman and Lennox, a draft pressure error on Trane, and an open limit on Rheem. Carrier uses two-digit codes instead.
| Flashes | GoodmanSingle blinking LED | TraneRed LED flash codes | LennoxSingle blinking LED | RheemGreen status + amber flame LEDs |
|---|---|---|---|---|
| 1 | System lockout: ignition retries or recycles exceeded. | — | Flame present with the gas valve de-energized. | Soft lockout. |
| 2 | Pressure switch stuck closed. | System lockout: ignition retries or recycles exceeded. | Pressure switch closed while the combustion air inducer is off. | Pressure switch circuit open. |
| 3 | Pressure switch stuck open. | Draft pressure error: a venting, pressure switch or inducer problem. | Pressure switch open while the combustion air inducer runs. | Limit circuit open. |
| 4 | Open high limit: the furnace is overheating. | Open temperature limit switch: the furnace is overheating. | Primary limit switch open: overheating. | Pressure switch circuit closed (when it should be open). |
| 5 | Flame sensed without the gas valve energized. | Flame sensed when no flame should be present. | Rollout switch open. | Twinning fault (only on twinned furnaces). |
| 6 | Open rollout switch: flame rolled out of the burner area. | 115 V polarity reversed, igniter (triac) fault, poor grounding or low system voltage. | Pressure switch cycle lockout. | — |
| 7 | Low flame signal. | Gas valve circuit error. | Lockout: burners failed to light. | — |
| 8 | — | Low flame sense. | Lockout: burners lost flame too many times. | — |
| 9 | — | Open inducer limit switch. | Line voltage polarity incorrect. | — |
Carrier furnace error codes
Also Bryant and Payne (Carrier brands). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →
Status LED: 2-digit code
Carrier gas furnaces with an amber or red status LED seen through the sight glass in the blower door (documented for the 58SB0A/58SB1A). Boards with a digital display show the same first two digits, followed by a decimal, for example 33.1. Count the short flashes (first digit), then the long flashes (second digit): 3 short + 3 long = code 33.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| 13 · 1 short + 3 long | Limit circuit lockout: a limit, draft safeguard, flame rollout or blocked-vent switch stayed open more than 3 minutes. Auto-resets after 3 hours. Replace a dirty air filter and open any closed supply or return vents. If the code returns, a technician must find why the furnace overheats. | High-limit switch$100–$375 |
| 14 · 1 short + 4 long | Ignition lockout: the furnace failed to light and prove flame in 4 tries. Auto-resets after 3 hours. Make sure the gas supply to the furnace is on (other gas appliances work). If it is, the usual causes are a dirty flame sensor, a failed igniter or the gas valve. | Flame sensor$80–$250 |
| 21 · 2 short + 1 long | Gas heating lockout: the control does not auto-reset. Turn the power off, wait 5 minutes and retry once. If it returns: a stuck gas valve relay on the control or a miswired gas valve. This needs a technician. | Furnace control board$300–$650 |
| 22 · 2 short + 2 long | Abnormal flame-proving signal: flame is sensed while the gas valve should be closed. The inducer keeps running. Likely a stuck-open or leaking gas valve. This needs a technician. | Gas valve$200–$800 |
| 23 · 2 short + 3 long | Pressure switch did not open. Obstructed pressure tubing or a pressure switch stuck closed. This needs a technician. | Visit $75–$200 |
| 24 · 2 short + 4 long | The 3-amp low-voltage (24 V) fuse on the control is blown. A short in the 24 V wiring, including the thermostat wires. The fuse must be replaced with a 3-amp fuse only. This needs a technician. | Visit $75–$200 |
| 31 · 3 short + 1 long | Pressure switch did not close or reopened. After 5 minutes open, the inducer shuts off for 15 minutes and retries. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Other causes: excessive wind, a disconnected pressure tube, a weak inducer motor or a failed pressure switch. | Draft inducer motor$400–$1,100 |
| 33 · 3 short + 3 long | Limit circuit fault: a limit, draft safeguard, flame rollout or blocked-vent switch is open. If it stays open over 3 minutes, it becomes code 13. Replace a dirty air filter and open any closed supply or return vents. Other causes: a loose blower wheel, a failed blower motor or capacitor, or a restricted vent. A tripped rollout switch needs a manual reset by a technician. | High-limit switch$100–$375 |
| 34 · 3 short + 4 long | Ignition proving failure: no flame sensed during ignition. The control retries 3 more times, then locks out (code 14). Check that the gas supply is on. Then the usual causes are a dirty flame sensor (Carrier lists 4.0–6.0 microamps as nominal), the igniter or the gas valve. | Flame sensor$80–$250 |
| 45 · 4 short + 5 long | Control circuitry lockout: flame circuit failure, stuck gas valve relay or software error. Auto-resets after 1 hour. Reset the power once. If the code repeats, Carrier says to replace the control board. | Furnace control board$300–$650 |
| Off | Off: no 115 V power to the control. Check the furnace breaker and the service switch near the furnace, and that the blower door is fully closed (its switch cuts power). | Visit $75–$200 |
| Rapid flashing | Rapid flashing: 115 V line polarity is reversed. The furnace will not run. The hot and neutral wires are swapped. This needs a technician. | Visit $75–$200 |
| 11 · 1 short + 1 long | No previous code stored. Codes clear after 72 hours. Run a heating cycle to see whether a new code appears. | — |
| 12 · 1 short + 2 long | Blower on after power-up. Normal: the blower runs 90 seconds if power returns during a call for heat. Nothing to fix. | — |
| Steady on | Steady on: the control has 24 V power. No fault. Nothing to fix. | — |
Goodman furnace error codes
Also Amana and Daikin (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →
Single blinking LED
Goodman 80% furnaces with one diagnostic LED on the control board (documented for the GMS8). The chart is also printed on the wiring diagram inside the furnace. Count the flashes between pauses.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| 1 flash | System lockout: ignition retries or recycles exceeded. Check that the gas supply is on, then reset the power once. If it locks out again, the flame sensor, igniter or gas valve are the usual suspects. | Flame sensor$80–$250 |
| 2 flashes | Pressure switch stuck closed. This needs a technician. | Visit $75–$200 |
| 3 flashes | Pressure switch stuck open. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Otherwise: a blocked or disconnected pressure hose, a weak inducer motor or a failed switch. | Draft inducer motor$400–$1,100 |
| 4 flashes | Open high limit: the furnace is overheating. Replace a dirty air filter and open any closed supply or return vents. If it continues, the blower or the limit switch needs a technician. | High-limit switch$100–$375 |
| 5 flashes | Flame sensed without the gas valve energized. A lingering flame or a slow-closing gas valve. This needs a technician. | Gas valve$200–$800 |
| 6 flashes | Open rollout switch: flame rolled out of the burner area. The rollout switch is a manual-reset safety device: a technician must find why it tripped. On some models this code also means an open control fuse. | Visit $75–$200 |
| 7 flashes | Low flame signal. Often a coated or oxidized flame sensor that needs cleaning. | Flame sensor$80–$250 |
| Off | Off: control failure. First check the furnace breaker, the service switch and that the blower door is closed. With power present and the LED still off, the control board is suspect. | Furnace control board$300–$650 |
| Rapid flashing | Rapid flashes: 115 V polarity reversed. Verify the ground. This needs a technician. | Visit $75–$200 |
| Steady on | Steady on: normal operation. Nothing to fix. | — |
3-character display
Newer Goodman, Amana and Daikin 80% single-stage furnaces with a 3-character display and three buttons (documented for the GR9S80, AR9S80, GD9S80 and AD9S80, 2023). Read the code on the display. Stored faults: press left or right until L6F shows, then press the center button.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| EE0 | Lockout after 3 ignition retries: no flame, or flame lost after lighting. Check that the gas supply is on. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Then: igniter, flame sensor or inducer. | Flame sensor$80–$250 |
| EE1 | Pressure switch closed at the start of the heating cycle. Sticking switch contacts or a short in the switch wiring. This needs a technician. | Visit $75–$200 |
| EE2 | Pressure switch not closed: the inducer runs but the furnace does not light. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. Otherwise: a pinched or blocked pressure hose, a weak inducer or a faulty switch. | Draft inducer motor$400–$1,100 |
| EE3 | Primary limit open: not enough air over the heat exchanger. The blower runs, no heat. Replace a dirty air filter and open any closed supply or return vents. Then: blower speed or a failed blower motor. | High-limit switch$100–$375 |
| EE4 | Flame sensed with no call for heat. A short in the flame-sense circuit, a lingering flame or a slow-closing gas valve. This needs a technician. | Gas valve$200–$800 |
| EE5 | Open fuse: short in the low-voltage wiring. Find and fix the short, then replace the fuse. This needs a technician. | Visit $75–$200 |
| EE6 | Weak flame signal. The furnace still runs. Clean or reposition the flame sensor; check gas pressure. | Flame sensor$80–$250 |
| EEL | Igniter circuit problem: wiring, a shorted igniter or a poor ground. This needs a technician. | Hot surface ignitor$100–$250 |
| EEA | Igniter relay fault, reversed 115 V polarity or poor ground. This needs a technician. | Furnace control board$300–$650 |
| EEb | Gas valve not energized when it should be. Gas valve wiring, or the control board. This needs a technician. | Furnace control board$300–$650 |
| EEC | Gas valve energized when it should not be. Gas valve wiring, or the control board. This needs a technician. | Furnace control board$300–$650 |
| E10 | Grounding fault or poor neutral connection. This needs a technician. | Visit $75–$200 |
| E11 | Open rollout switch. Gas pressure, burner alignment or a restricted burner. This needs a technician. | Visit $75–$200 |
| EEn | Igniter open (broken or disconnected). Check the igniter wiring; replace a damaged igniter. | Hot surface ignitor$100–$250 |
| EEJ | Inducer relay error. Goodman says to replace the control board. | Furnace control board$300–$650 |
| EEE | Internal control board fault. Goodman says to replace the control board. | Furnace control board$300–$650 |
| EbL | Hard lockout: the blower motor draws very little current. Loose motor wiring or a burnt blower motor. This needs a technician. | Blower motor replacement (indoor)$500–$2,300 |
| EbU | Hard lockout: the blower motor draws too much current. Loose wiring, or line wires reversed at the control. This needs a technician. | Blower motor replacement (indoor)$500–$2,300 |
| EAL | The R-32 sensor detected a refrigerant leak. Heating stops and only the fan runs. Normal operation resumes once no leak is detected and a 5-minute delay has passed. Have the indoor coil checked for a leak. | Refrigerant leak repair$200–$1,500 |
| EAF | Lost communication with the R-32 sensor. Only the fan runs. Loose or damaged sensor wire, or no R-32 cooling unit paired. This needs a technician. | Visit $75–$200 |
| EAS | R-32 sensor fault. Only the fan runs. Replace the R-32 sensor. This needs a technician. | Visit $75–$200 |
| EAr | A2L relay fault on the control board. Only the fan runs. Cycle the power once; if it repeats, the board is replaced. | Furnace control board$300–$650 |
| idL | Idle: normal operation. Nothing to fix. | — |
Trane furnace error codes
Also American Standard (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →
Red LED flash codes
Trane and American Standard furnaces with a red "error" LED on the integrated furnace control (documented for the *UX2/*DX2 two-stage furnaces). Count the red flashes between pauses. On power-up, the control replays its last 4 faults, newest first.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| 2 flashes | System lockout: ignition retries or recycles exceeded. Check that the gas supply is on and reset the power once. If it locks out again: flame sensor, igniter or gas valve. | Flame sensor$80–$250 |
| 3 flashes | Draft pressure error: a venting, pressure switch or inducer problem. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| 4 flashes | Open temperature limit switch: the furnace is overheating. Replace a dirty air filter and open any closed supply or return vents. | High-limit switch$100–$375 |
| 5 flashes | Flame sensed when no flame should be present. This needs a technician. | Gas valve$200–$800 |
| 6 flashes | 115 V polarity reversed, igniter (triac) fault, poor grounding or low system voltage. This needs a technician. | Hot surface ignitor$100–$250 |
| 7 flashes | Gas valve circuit error. This needs a technician. | Gas valve$200–$800 |
| 8 flashes | Low flame sense. A dirty flame sensor is a common cause. | Flame sensor$80–$250 |
| 9 flashes | Open inducer limit switch. This needs a technician. | Draft inducer motor$400–$1,100 |
| 10 flashes | Inducer communication error. This needs a technician. | Draft inducer motor$400–$1,100 |
| Solid red | Solid red: internal gas valve error or low thermostat (24 V) voltage. This needs a technician. | Furnace control board$300–$650 |
| Solid red + green | Solid red with solid green: continuous reset from a blown fuse or an internal error. This needs a technician. | Furnace control board$300–$650 |
Lennox furnace error codes
Lennox gas furnaces. Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →
Single blinking LED
Lennox furnaces whose integrated control has one LED and a push button for code recall (documented for the ML195UH, 2019). Count the flashes. Press the button under 5 seconds to replay the last 5 faults, newest first.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| 1 flash | Flame present with the gas valve de-energized. This needs a technician. | Gas valve$200–$800 |
| 2 flashes | Pressure switch closed while the combustion air inducer is off. This needs a technician. | Visit $75–$200 |
| 3 flashes | Pressure switch open while the combustion air inducer runs. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| 4 flashes | Primary limit switch open: overheating. Replace a dirty air filter and open any closed supply or return vents. | High-limit switch$100–$375 |
| 5 flashes | Rollout switch open. This needs a technician. | Visit $75–$200 |
| 6 flashes | Pressure switch cycle lockout. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| 7 flashes | Lockout: burners failed to light. Check that the gas supply is on. Then: igniter, flame sensor or gas valve. | Hot surface ignitor$100–$250 |
| 8 flashes | Lockout: burners lost flame too many times. A dirty flame sensor is a common cause. This needs a technician. | Flame sensor$80–$250 |
| 9 flashes | Line voltage polarity incorrect. This needs a technician. | Visit $75–$200 |
| Off | LED off: no power to the control, or a control hardware fault. Check the furnace breaker, the service switch and that the blower door is closed. | Furnace control board$300–$650 |
| Steady on | LED on: normal operation. Nothing to fix. | — |
Display with E-codes
Newer Lennox furnaces whose control shows E-codes such as E250 (documented for the ML180UHVK, 2025). Read the code on the display. E000 means no error in memory.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| E110 | Line voltage low. Waits for recovery. This needs a technician. | Visit $75–$200 |
| E111 | Line voltage polarity reversed. This needs a technician. | Visit $75–$200 |
| E113 | Line voltage high. This needs a technician. | Visit $75–$200 |
| E117 | Poor ground detected. This needs a technician. | Visit $75–$200 |
| E125 | Control hardware failure. 5-minute lockout. This needs a technician. | Furnace control board$300–$650 |
| E200 | Hard lockout: rollout switch open or previously opened. This needs a technician. | Visit $75–$200 |
| E204 | Gas valve relay problem. This needs a technician. | Furnace control board$300–$650 |
| E223 | Low pressure switch failed to close (stuck open). Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| E224 | Low pressure switch failed to open (stuck closed). This needs a technician. | Visit $75–$200 |
| E227 | Low pressure switch opened during the run or the ignition trial. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| E240 | Low flame current in heating mode. A dirty flame sensor is a common cause. | Flame sensor$80–$250 |
| E241 | Flame sensed out of sequence and still present. This needs a technician. | Gas valve$200–$800 |
| E250 | Primary limit switch opened: overheating. Replace a dirty air filter and open any closed supply or return vents. | High-limit switch$100–$375 |
| E270 | 60-minute soft lockout: flame failure on ignition after the maximum retries. Check that the gas supply is on. Then: igniter, flame sensor or gas valve. | Hot surface ignitor$100–$250 |
| E271 | 60-minute soft lockout: pressure switch open during ignition retries. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| E272 | 60-minute soft lockout: pressure switch kept opening while heating. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| E273 | 60-minute soft lockout: flame lost too many times while heating. This needs a technician. | Flame sensor$80–$250 |
| E274 | 60-minute soft lockout: limit open over 3 minutes. Replace a dirty air filter and open any closed supply or return vents. | High-limit switch$100–$375 |
| E275 | 60-minute soft lockout: flame out of sequence, now gone. This needs a technician. | Gas valve$200–$800 |
| E290 | Igniter circuit fault: failed igniter or triggering circuit. This needs a technician. | Hot surface ignitor$100–$250 |
| E292 | Indoor blower unable to start (variable speed). This needs a technician. | Blower motor replacement (indoor)$500–$2,300 |
| E150 | Refrigerant leak detected: thermostat lockout. Have the indoor coil checked for a leak. This needs a technician. | Refrigerant leak repair$200–$1,500 |
| E151 | Refrigerant leak sensor #1 fault (E152: sensor #2). This needs a technician. | Visit $75–$200 |
| E154 | Refrigerant leak sensor #1 communication lost (E155: sensor #2). This needs a technician. | Visit $75–$200 |
| E163 | Refrigerant leak detector control failure. This needs a technician. | Furnace control board$300–$650 |
| E000 | No error in memory. Nothing to fix. | — |
Rheem furnace error codes
Also Ruud (same manufacturer). Codes change between control boards, so confirm yours against the chart printed inside the furnace door. Decode it step by step →
Green status + amber flame LEDs
Rheem and Ruud furnaces with a green STATUS LED and an amber FLAME LED on the control (documented for the (-)GPN/(-)GPP series). Count the green blinks for faults. The amber LED reports the flame signal.
| Code | What it means · what to do | Most likely part |
|---|---|---|
| Green 1 flash | Green, 1 blink: soft lockout. Reset the system power and start over. If it repeats: flame sensor, igniter or gas valve. | Flame sensor$80–$250 |
| Green 2 flashes | Green, 2 blinks: pressure switch circuit open. Outside, check that the furnace vent pipe is not blocked by snow, ice, leaves or a nest. | Draft inducer motor$400–$1,100 |
| Green 3 flashes | Green, 3 blinks: limit circuit open. Replace a dirty air filter and open any closed supply or return vents. | High-limit switch$100–$375 |
| Green 4 flashes | Green, 4 blinks: pressure switch circuit closed (when it should be open). This needs a technician. | Visit $75–$200 |
| Green 5 flashes | Green, 5 blinks: twinning fault (only on twinned furnaces). This needs a technician. | Visit $75–$200 |
| Amber slow blink | Amber slow blink: marginal flame sense. A dirty flame sensor is a common cause. | Flame sensor$80–$250 |
| Amber rapid blink | Amber rapid blink: unexpected flame. This needs a technician. | Gas valve$200–$800 |
| Amber steady | Amber steady: normal flame sense. Nothing to fix. | — |
| Amber off | Amber off: no flame present (normal between cycles). Nothing to fix unless the furnace should be heating. | — |
What a furnace error code usually costs to fix
Most codes point to one of a handful of parts. A technician’s diagnostic visit costs $75–$200; tell them the code you read, it saves time.
| Part | Repair cost |
|---|---|
| Flame sensor | $80–$250 |
| Hot surface ignitor | $100–$250 |
| High-limit switch | $100–$375 |
| Draft inducer motor | $400–$1,100 |
| Gas valve | $200–$800 |
| Furnace control board | $300–$650 |
| Blower motor replacement (indoor) | $500–$2,300 |
| Transformer | $100–$250 |
Frequently asked questions
Why is my furnace blinking red?
The control board is reporting a fault. Count the flashes between pauses and look the number up for your brand: the most common causes are an overheating furnace (open limit, often a dirty filter), a vent or pressure switch problem, or failed ignition. On Trane furnaces a solid red light is also a fault.
What does it mean when my furnace blinks 3 times?
It depends on the brand. Goodman (single-LED boards): pressure switch stuck open. Trane: draft pressure error. Lennox (single-LED boards): pressure switch open while the inducer runs. Rheem (green LED): limit circuit open. Start by checking that the vent pipe outside is clear and the filter is clean.
Should I reset my furnace when the light is blinking?
Read the code first, then reset the power once. Carrier ignition and limit lockouts clear themselves after 3 hours and Lennox soft lockouts after 60 minutes. If the same code comes back, there is a fault to fix; a tripped rollout switch in particular needs a technician.
Is a steady light on the furnace board normal?
Usually yes. A steady LED means normal operation on Goodman and Lennox single-LED boards, and 24 V power on Carrier. The exception is Trane: a solid red LED there signals a gas valve error or low thermostat voltage.
Where is the error code chart on my furnace?
On a label inside the furnace door (often the blower door) or on the wiring diagram glued inside the cabinet. Carrier calls it the service label. If yours differs from this page, follow the label: it matches your control board.
How much does it cost to fix a furnace error code?
It depends on the part: flame sensor $80–$250, igniter $100–$250, limit switch $100–$375, inducer motor $400–$1,100, control board $300–$650. Many limit codes are fixed for the price of an air filter.
- Carrier — 58SB0A/58SB1A Installation, Start-up, Operating and Service Instructions (Fig. 44 service label, Fig. 51)
- Goodman — GMS8 Technical Manual RT6621031r2 (Nov 2013), control LED codes
- Goodman / Daikin — Service and Troubleshooting, 80% Single Stage Gas Furnaces RS6621301 (Nov 2023)
- Trane — Installer’s Guide 18-CD25D1-6, *UX2/*DX2 furnaces (IFC red LED flash codes)
- Lennox — ML195UH Installation Instructions 507268-03 (02/2019)
- Lennox — ML180UHVK Installation Instructions 508547-01 (12/2025)
- Rheem — (-)GPN/(-)GPP Installation Instructions 92-24161-38-01 (troubleshooting chart)
- HomeGuide — Furnace Repair Cost (2026)
Estimates for planning only. Prices vary by region, home, and contractor. Gas, refrigerant, and high-voltage work must be done by a licensed technician.